Modern Dental Technology

Herident Dental Clinic utilizes modern and advanced equipment to support the process of creating treatment plans and delivering precise, fast, and efficient treatments for customers.

The facilities are meticulously invested in, with clinics designed separately to provide a comfortable and quiet space, ensuring a relaxing experience for customers throughout the treatment process.

Herident Dental Clinic is currently a reputable dental system in Vietnam, with a team of highly skilled doctors, deep empathy for patients, and a community-focused dental care model. It serves all social classes with the best quality and services.

Clinic Space Experience

Herident Dental Clinic uses modern, advanced equipment to support the process of creating treatment plans and providing accurate, fast, and efficient treatments for customers. The facilities are meticulously invested in, with clinics designed to create a comfortable and quiet space, ensuring relaxation for customers throughout the treatment process.

  • Sterilization and hygiene are always a top priority.
  • Separate and completely sterile environments meet Ministry of Health standards.
  • GENORAY PAPAYA 3D Plus Dental X-ray machine.
  • Suntem 570 ensures quietness, safety, and comfort for users.
View More

8-Step Dental Sterilization Protocol


8 steps will be processed in 4 areas following the one-way rule, from used to clean.

  • Area 1: Cleaning and Disinfection
  • Area 2: Instrument Packaging
  • Area 3: Sterilization through Autoclaving
  • Area 4: Storage and Preservation
Step 1
Cleaning and handling contaminated instruments after treatment
Step 2
Transporting contaminated instruments to the processing area to prevent cross-contamination
Step 3
Soaking and ultrasonic cleaning of instruments with disinfectant solutions
Step 4
Clean the disinfectant solution using a washing machine with warm water and allow it to dry naturally.
Step 5
Package the instruments according to standards, with a heat indicator label, clearly stating the date.
Step 6
Sterilize the instruments using a steam autoclave according to the pre-set automatic process.
Step 7
Store the instruments in a UV sterilization cabinet according to the recommended usage period.
Step 8
Distribute and transport the instruments cleanly to the treatment room for use with each patient.
Prev
Next

Combining the standards set by the Ministry of Health and global knowledge of sterilization practices in surgery, the sterilization protocol at Herident is a result of years of research and personal experience by Dr. Dang Trieu Hung, MD, PhD. to ensure that the dental environment remains clean, safe, and free from cross-contamination. The protocol is built around three key highlights:

  • Closed-loop process: one-way flow from used to clean instruments
  • Dividing the entire sterilization process into 4 distinct zones; each staff member is thoroughly trained to follow the 8-step sterilization process meticulously, as required by regulations. We place a strong emphasis on checking the expiration date and monitoring the storage temperature of each instrument set.
  • Modern equipment, regularly inspected and maintained.

We understand that safety is the greatest concern when choosing a healthcare solution. Our 23-year journey of empathizing with every concern of our clients has been the foundation that allows Herident to serve with dedication and grow stronger to this day.